800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA / CARIBBEAN
4
4
A
pp
l
i
cat
i
on:
T
he
S
Y actuators are NEMA 4X rated and desi
g
ned to meet
t
he needs of HVAC and Commercial applications. Offered on
Belimo standard and high performance valve series, these
actuators are available for on/off and modulating applications
.
Depending on the application, they are available in 24 VAC/
VDC, 120 VAC and 230 VAC
.
Technical Data
Electrical connectio
n
½” conduit connector, screw terminal
s
Motor protection H Class insulation (SY-1),
F Class (SY-2…12)
Gear trai
n
high allo
y
steel gear sets,
s
el
f
lockin
g
Operating range (SY…-110) on/off, floating point
(
SY...120MFT
)
2-10 VDC, 4-20 mA, 0-10
VD
C
Sensitivit
y
(
SY…120MFT
)
0.4 mA/200mV
R
eversa
l
h
ysteres
is
(
SY…120MFT
)
1.0 mA/500mV
Feedbac
k
(SY…120MFT) 2-10 VDC
Angle of rotation 90°
Direction of rotatio
n
rever
s
ibl
e
P
o
s
ition indicatio
n
top mounted domed indicator
Internal humidity control resistive heating elemen
t
A
ux
ili
ary sw
i
tc
h
e
s
factory set for 5° and 85° change of stat
e
SY1:
(
2
)
SPDT, min 1 mA, 24 VAC; max
3A
,
250 VAC.
SY2-12:
(
2
)
SPDT, min 1 mA, 24 VAC;
max 5A, 250 VAC.
Ambient temperature -22°F to +150°F [-30°C to +65°C]
Humidit
y
range up to 95%
Housing type IP67, NEMA 4X
Housing materia
l
die cast aluminum allo
y
Agency listing
s
ISO
,
CE
,
cCSAus
Note: Leakage current is possible (<3.5 mA).
Connect ground before appl
y
ing voltage
.
Power Suppl
y
120 VAC 50/60Hz, sin
g
le phas
e
Model Torque
Speed
60Hz
Speed
50Hz
Power
Consumption
Duty Cycle
Override WeightOn/Off Proportional
SY1-110(P)
3
5Nm/310 in-lb
s
12
s
13s
0
.
5
A30
%
75
%
8
mm Wr
e
n
ch
2
.0kg/4.9 lb.
S
Y2-120
(
MFT
)
90Nm
/
801 in-lb
s
15s
17s
1
.
0
A 30
%
75
%
H
a
n
d
Wh
eel
11k
g/
24.5 lb.
SY3-120(MFT) 150Nm/1335 in-lb
s
22s
2
6s
1
.0A 30
%
75
%
Hand Whee
l
11k
g
/24.5 lb.
SY4-120(MFT
)
400Nm/3560 in-lb
s
1
6
s
18
s
1
.
3A
30
%
75
%
H
an
d
Wh
ee
l
22kg/48.5 lb.
S
Y5-120
(
MFT
)
500Nm
/
4450 in-lb
s
22
s
25s
1
.
5
A 30% 75% H
a
n
d
Wh
eel
22k
g/
48.5 lb.
SY6-120
(
MFT
)
650Nm
/
5785 in-lb
s
2
8s
3
1
s
1
.
8
A 30% 75% H
a
n
d
Wh
eel
22k
g
/48.5 lb.
S
Y7-120
(
MFT
)
1000Nm
/
8900 in-lbs
46s
55s
3
.2A 30% 75% H
a
n
d
Wh
eel
36k
g/
79.5 lb.
S
Y8-120
(
MFT
)
1500Nm
/
13350 in-lbs
46
s
55
s
4
.
0A
30% 75%
H
an
d
Wh
ee
l
36kg
/
79.5 lb.
SY9-120
(
MFT
)
2000Nm/17800 in-lbs
5
8s
7
0s
3
.2A 30
%
50
%
Hand Whee
l
5
6k
g
/123.5 lb
.
S
Y10-120
(
MFT
)
2500Nm
/
22250 in-lbs
58s
70s
4
.
0
A 30% 50% H
a
n
d
Wh
eel
5
6k
g/
123.5 lb
.
SY11-120
(
MFT
)
3
000Nm
/
26700 in-lbs
58s
70s
3
.
0
A30
%
50
%
H
a
n
d
Wh
eel
5
6k
g
/123.5 lb
.
SY12-120(MFT)
3
500Nm/31150 in-lbs
58
s
70
s
4
.
0A
30% 50%
H
an
d
Wh
ee
l
5
6kg/123.5 lb
.
SY...120V Series Non-Spring Return Actuator